How to change off Grid Inverter S/N

How to change off Grid Inverter S/N Once you replace control board, Please kindly set your original Inverter S/N on control board. Inverter S/N is stored in control board chip. Before you use softwares below, please make sure that you have installed correct driving program for com board. You can read the post below and …

How to change off Grid Inverter S/N Read More »

113.00, 114.00 Firmware of SPF 5000ES

113.00, 114.00 firmware of SPF 5000ES Firmware Version 113.00, 114.00 Explaination 113.00 firmware version is for 28067 114.00 firmware version is for STM103 Because previously, we lack 2809 Chip, accordingly we use 28067 and STM103 chip instead Other firmwares can’t be used for this kind of chips. Please highlight this

SPF 5000ES/sPF 5000TL HVM WPV 17 warning Troubleshooting

SPF 5000ES 17 warning Troubleshooting 17 warning meaning AC Output Phase loss Triggering Condition: 1. Host inverter detects Lack of S phase or T phase 2. Lasting time 400ms( approximately 100ms*4); Cancelling Condition: Host Inverter has detected that both S and T phase exist. Lasting time has exceeded 100ms Solution: 1. Check 23th option on …

SPF 5000ES/sPF 5000TL HVM WPV 17 warning Troubleshooting Read More »

The Principle Of Parallel Mode Working On Off Grid Inverter

The principle of Parallel mode working When parallel system works on same phase like 230V, you just need to connect Parallel cable and current sharing cable , then inverters will compete and produce host and slave inverter automatically. What if parallel system works on 3 phases, you need to set 23th option, and set P1,P2,P3 …

The Principle Of Parallel Mode Working On Off Grid Inverter Read More »

How to modify inverter S/N on off grid inverter

How to change inverter S/N on off grid inverter SPF 5000ES/SPF 5000TL HVM WPV/SPF 5000TL HVM use com tool to modify inverter S/N; SPF 3000TL HVM 24/48 use modscan software to modify inverter S/N. tool Download Com Tool Usb&Com3.2 En.exe Download modscan32 V7 A004 Download modscan32 V7 A004 Download SPF 5000ES/SPF 5000TL HVM WPV Procedures: …

How to modify inverter S/N on off grid inverter Read More »

How to solve negative value of power generation on SPF 5000TL HVM

How to solve negative value of power generation on SPF 5000TL HVM Phenomenon Reason Analysis Control board memory data overflow Solution You can learn how to upgrade inverter via https://www.amosplanet.org/how-to-upgrade-off-grid-inverter/ password: open20220621 1. MPPT firmware needs to be upgraded as TMS320F28027_sk002.07_202202180952.bin MPPT Fireware Download ( Specially for power generation negative value) Please note when upgrading …

How to solve negative value of power generation on SPF 5000TL HVM Read More »

How to adjust to battery voltage on sPF 5000ES Or sPF 5000TL hvm WPV

How to adjust to battery voltage on sPF 5000ES Or sPF 5000TL hvm WPV Procedures Please note that the method just can be used for several voltage difference between real battery voltage and LCD Display. If the difference is large, maybe board is something wrong. Only connect battery to inverter( Don’t connect inverter to utility, …

How to adjust to battery voltage on sPF 5000ES Or sPF 5000TL hvm WPV Read More »