Case Sharing: 2 MAX 60K TL3 LV with SEM can’t produce power normally when exporting current limitation function enabled

2 MAX 60K TL3 LV with SEM has exporting current limitation issue Phenomenon When exporting current limitation function has been enabled, 2 inverters produce very little Power In the beginning, I thought it is definitely wrong CT position, but after local engineer Eliud went to site and check everything, it is not CT installation issue …

Case Sharing: 2 MAX 60K TL3 LV with SEM can’t produce power normally when exporting current limitation function enabled Read More »

How to confirm if mainboard inside max Series inverter is normal

How to confirm if mainboard inside max Series inverter is normal Boost Circuit and DC-AC circuit have some IGBTs, they bear large current, if mainboard can’t work, most of time, it is caused by them, so when you suspect that mainboard is faulty, you can test them. Turn to Diode position on multimeter BUS+, BUS- …

How to confirm if mainboard inside max Series inverter is normal Read More »

MAX series Firmware Download

MAX series Firmware Download MAX 50-80K TL3 LV ( Common Version ) Newest Firmware TIAA-22xxxxxx: 043.1159521 TIAA-xx20xxxx:043.1159619 TIAA-xxxx04xx:043.1159703 ZBBA-0020:043.1231319 Old Firmware TIAA-20xxxxxx:043.1159519 TIAA-xx17xxxx:043.1159616 TIAA-xxxx04xx:043.1159703 ZBBA-0014:043.1231313 043.1159519.hex, 043.1159616.hex, TIAA-xxxx04xx-CPLD.hex, 043.1231313.bin should be upgraded. About how to upgrade MAX inverter, please read the post below: https://www.amosplanet.org/how-to-upgrade-max-series-inverter/ When local upgrading, *.bin file should be upgraded finally, the previous …

MAX series Firmware Download Read More »

How to analyze issue of max series based on History data

Datalogger will upload many important data into server. They are stored in History data. You can download it and read key parameters. 1. How to download History data from server Please note that just Distribuotr or installer or Our service engineer account can download history data. a. Access OSS account via http://oss.growatt.com/login?lang=en b. Download History …

How to analyze issue of max series based on History data Read More »

Degrade mode on MAX series introduction

Degrade Mode of MAX series introduction 1. How to check Degrade mode a. access installer or Distributor account via oss.growatt.com b. Download History data from plant C. Open excel file D. Find “Degrade” Column E. Degrade number Meaning 1) mode number: 0 No Degrade 2) mode number: 1 The bus voltage exceeds 850V and AC …

Degrade mode on MAX series introduction Read More »