MAX 185~253KTL3-X HV Introduction 1.Datasheet 2.User manual 3. Product Appearance MAX 185K, 196K, 216K 9 MPPT String Product Appearance MAX 225K, 250K 12 MPPT String Product Appearance MAX 230K, 253K 15 MPPT Product Appearance 1) There are a total of 15 MPPT channels on the BOOST side. Each 3 MPPT share a BOOST-IGBT module. Each …
MAX 100-150KTL3-X Upgrading Guide Take the code TNAA11090300/ZBBA-0020 as an example. TNAA11090300 is usually called the DSP code. ZBBA-0020 is the M3 code. The following are the precautions for various aspects of remote upgrade code . It is recommended to upgrade at night 1. DSP Firmware a. Recommended upgrading sequence. b. Recommended upgrading sequence. c. …
Step One : make sure your inverter can link to the cyber , and you know about the OSS plantform, and should know the real reason Step Two : measure the realtime voltage of the tapping point (grid connection point) , Six voltage , here is the template (N for Neutral , G for ground …
how to handle AC V outrange of MAC/MAX (OSS remote setting) – (warning code 300) Read More »
How to modify model number on MAX 50-80K TL3 LV 1.What’s Model Number? Model number has defined some basic functions like ISO, GFCI, PID, AFCI, Power segment etc. If you want to disable or enable these functions, you can modify model number. Like Model A0B0D0T4PFUDM8S1 Method 1 If you have USB-485 or USB-232-485 tool, you …
How to check if fans are working on MAX 50-80K TL3 LV When you find that fans are not working, you can set 232 register address and check if fans are working. For MAX 50-80K series, there are 4 fans, 3 external fans and 1 internal fan. Procedures Set the 231 register as 1, start …
How To Check If Fans Are Working On MAX 50-80K TL3 LV Read More »
2 MAX 60K TL3 LV with SEM has exporting current limitation issue Phenomenon When exporting current limitation function has been enabled, 2 inverters produce very little Power In the beginning, I thought it is definitely wrong CT position, but after local engineer Eliud went to site and check everything, it is not CT installation issue …
MAX 100-150KTL3-X LV/MV Troubleshooting Fault Reading As shown in the figure: If inverter goes into fault mode, every led light represent one number, from right to left , it is 2 to the zero power, 2 to the 1 power, 2 to the 2 power, , 2 to the 3 power ,.. until 2 to …