Amosplanet

Stay Hungry, Stay Foolish

Month: November 2022

SPF 5000ES/sPF 5000TL HVM WPV 17 warning Troubleshooting

SPF 5000ES 17 warning Troubleshooting 17 warning meaning AC Output Phase loss Triggering Condition: 1. Host inverter detects Lack of S phase or T phase 2. Lasting time 400ms( approximately 100ms*4); Cancelling Condition: Host Inverter has detected that both S and T phase exist. Lasting time has exceeded 100ms Solution: 1. Check 23th option on …

SPF 5000ES/sPF 5000TL HVM WPV 17 warning Troubleshooting Read More »

How to confirm if mainboard inside max Series inverter is normal

How to confirm if mainboard inside max Series inverter is normal Boost Circuit and DC-AC circuit have some IGBTs, they bear large current, if mainboard can’t work, most of time, it is caused by them, so when you suspect that mainboard is faulty, you can test them. Turn to Diode position on multimeter BUS+, BUS- …

How to confirm if mainboard inside max Series inverter is normal Read More »

How to use Can box to read Hope battery info.

How to use can box to read hope battery info. 1. CANalyst-II 2. CANalyst-II installment CANalyst-II diagram,“1”is CAN1-H,“2”is CAN1-L,”3”is CAN2-H,“4”is CAN2-L; 3. Hope Battery 3.3KWh Cable can be plugged in Link-IN or Link-OUT, Procedures: a) Insert Crystal Plugs to Link-in and Link-Out Like below firstly b) Unplug one of Crystal plugs c) Connect upper software …

How to use Can box to read Hope battery info. Read More »