Amosplanet

Stay Hungry, Stay Foolish

High Frequency Inverter

How to solve negative value of power generation on SPF 5000TL HVM

How to solve negative value of power generation on SPF 5000TL HVM Phenomenon Reason Analysis Control board memory data overflow Solution You can learn how to upgrade inverter via https://www.amosplanet.org/how-to-upgrade-off-grid-inverter/ password: open20220621 1. MPPT firmware needs to be upgraded as TMS320F28027_sk002.07_202202180952.bin MPPT Fireware Download ( Specially for power generation negative value) Please note when upgrading …

How to solve negative value of power generation on SPF 5000TL HVM Read More »

How to adjust to battery voltage on sPF 5000ES Or sPF 5000TL hvm WPV

How to adjust to battery voltage on sPF 5000ES Or sPF 5000TL hvm WPV Procedures Please note that the method just can be used for several voltage difference between real battery voltage and LCD Display. If the difference is large, maybe board is something wrong. Only connect battery to inverter( Don’t connect inverter to utility, …

How to adjust to battery voltage on sPF 5000ES Or sPF 5000TL hvm WPV Read More »

Off Grid Inverter 02 warning

Off Grid Inverter 02 warning Over temperature warning Testing method 1: a. Access OSS system https://oss.growatt.com/login?lang=en b. Download History data Temperature 1: temperature sensor on mainboard Temperature2: Temperature sensor on DC-DC circuit of mianboard Temperature3: Temperature sensor on MPPT board c. You can confirm which board needs to be replaced based on the 3 temperature …

Off Grid Inverter 02 warning Read More »

How to commission the communication between lithium-ion battery and SPF 3500-5000ES

commissioning the communication between lithium-ion battery and SPF 3500-5000ES Download: Note: Pylontech UP5000 is same with US2000C US3000C, all of them can communication with off grid inverter Battery brand in our list has been tested in our lab. Some other battery manufactors has matched our inverter modbus protocol type , but they havn’t been tested …

How to commission the communication between lithium-ion battery and SPF 3500-5000ES Read More »

How to adjust to battery voltage of SPF 5000TL HVM /SPF 3000TL HVM 24/48 on lcd display

How to adjust to battery voltage of off grid inverter on lcd display Procedures: Please note that the method just can be used for several voltage difference between real battery voltage and LCD Display. If the difference is large, maybe board is something wrong. Only connect battery to inverter( Don’t connect inverter to utility, PV …

How to adjust to battery voltage of SPF 5000TL HVM /SPF 3000TL HVM 24/48 on lcd display Read More »