amosplanet

MIN Series History Data Meaning

MIN series History data meaning MIN 2.5-6KTL-X 1. MODEL Number: S01B01D04T00P0FU01M0032 S:Safety 0-26 B: Function1 D:Display ODM manufacturer T: Function 2 P:Function3 U:Environment, Machine working environment, AC voltage range, PV ground M:Power power section, accuracy is 100W Safety S00: Null S01: VDE0126 S02: G99 S03: AS4777_Australia S04: CEI0_21 S05: cS_SP1663 S06: reserved Xila S07: N4105 …

MIN Series History Data Meaning Read More »

How to Add End User Plant into Installer Account or Distributor Account

How to add end user plant into installer account or distributor account Many clients don’t know how to add end user plant into Installer account or distributor account. Firstly ,, you need to know what end user account is, which is logged in on server.growatt.com. Secondly, you just need to fill in installer code into …

How to Add End User Plant into Installer Account or Distributor Account Read More »

Hope Battery troubleshooting

Hope Battery troubleshooting This post has introduced how to disassemble battery , how to use upper software, and basic pin layout etc. Hope battery Operation Hope battery Fault Clearing When battery enter fault state, please click Blue arrow position to clear fault

Case Sharing: 2 MAX 60K TL3 LV with SEM can’t produce power normally when exporting current limitation function enabled

2 MAX 60K TL3 LV with SEM has exporting current limitation issue Phenomenon When exporting current limitation function has been enabled, 2 inverters produce very little Power In the beginning, I thought it is definitely wrong CT position, but after local engineer Eliud went to site and check everything, it is not CT installation issue …

Case Sharing: 2 MAX 60K TL3 LV with SEM can’t produce power normally when exporting current limitation function enabled Read More »

Modbus Protocol type for Grid, Hybrid Inverter

Modbus Protocol type for Grid, Hybrid Inverter 1. Applicable for these models below TL-X/TL-XH/TL-XH US(MIN Type) TL3-X(MAX、MID、MAC Type) MAX 1500V、MAX-X LV MAX250KTL3-X HV MOD TL3-XH Storage(MIX Type) Storage(SPA Type) Storage(SPH Type) 2. register address meaning Holding register: 这个是电网电压高于某个值或者低于某个值才会触发降载,与安规有关 grid voltage is higher than a certain value or lower than a certain value before degrading is …

Modbus Protocol type for Grid, Hybrid Inverter Read More »