nagative power generation value on SPF 6KT HVM Phenomenon Solution: Upgrade MPPT board and modify Etotal Procedures 1.Download Speical MPPT board Firmware for SPF 6KT HVM SPF 6KT HVM MPPT Firmware Download for Negative power generation value 2. Make sure that battery and PV system should be connected to inverter 3. Upgrade MPPT board via …

How to solve nagative power generation value on SPF 6KT HVM Read More »

What’s MPPT From Solar Inverter

What’s MPPT From Solar Inverter When people talk about solar inverter, MPPT parameters always are referred. It is pretty important when in the stage of procuring, installing and commissioning solar plant. What’s MPPT MPPT is the abbreviation of Max Power Point Tracking, In the PV system, the output power of solar panels is determined by …

What’s MPPT From Solar Inverter Read More »

How to analyze off grid inverter issues based on History data

How to analyze off grid inverter issues based on History data When off grid inverter is something wrong, you can analyze the issue via History data firstly 1. SPF 5000ES/SPF 5000TL HVM WPV History Data Download a. Access server.growatt.com b. Download History Data c. Download History Data Example: d. Meaning of History data fw_version Old …

How to analyze off grid inverter issues based on History data Read More »

How to modify register address value on shinemaster

How to modify register address value on shinemaster 1. How to modify register address on Shinemaster via server.growatt.com a. Access server.growatt.com b. Select “Datalogger“ c. Select “Datalogger Setting“ d. Select “Advanced set” and Type password: growatt+today’s date like growatt20220715 e. Read register address value you want F. Modify register address value 2. Shinemaster Register address …

How to modify register address value on shinemaster Read More »

MAX series Firmware Download

MAX series Firmware Download MAX 50-80K TL3 LV ( Common Version ) Newest Firmware TIAA-22xxxxxx: 043.1159521 TIAA-xx20xxxx:043.1159619 TIAA-xxxx04xx:043.1159703 ZBBA-0020:043.1231319 Old Firmware TIAA-20xxxxxx:043.1159519 TIAA-xx17xxxx:043.1159616 TIAA-xxxx04xx:043.1159703 ZBBA-0014:043.1231313 043.1159519.hex, 043.1159616.hex, TIAA-xxxx04xx-CPLD.hex, 043.1231313.bin should be upgraded. About how to upgrade MAX inverter, please read the post below: https://www.amosplanet.org/how-to-upgrade-max-series-inverter/ When local upgrading, *.bin file should be upgraded finally, the previous …

MAX series Firmware Download Read More »

How to solve negative value of power generation on SPF 5000TL HVM

How to solve negative value of power generation on SPF 5000TL HVM Phenomenon Reason Analysis Control board memory data overflow Solution You can learn how to upgrade inverter via https://www.amosplanet.org/how-to-upgrade-off-grid-inverter/ password: open20220621 1. MPPT firmware needs to be upgraded as TMS320F28027_sk002.07_202202180952.bin MPPT Fireware Download ( Specially for power generation negative value) Please note when upgrading …

How to solve negative value of power generation on SPF 5000TL HVM Read More »