How to confirm if mainboard inside max Series inverter is normal

How to confirm if mainboard inside max Series inverter is normal Boost Circuit and DC-AC circuit have some IGBTs, they bear large current, if mainboard can’t work, most of time, it is caused by them, so when you suspect that mainboard is faulty, you can test them. Turn to Diode position on multimeter BUS+, BUS- …

How to confirm if mainboard inside max Series inverter is normal Read More »

How to commission smart meter communication with inverter directly

How to commission smart meter communication with inverter directly When commissioning the communication between single inverter and smart meter, you need to enable exporting current limitation function on inverter, and set correct smart meter address and connect correct 485 wire. MAX inverter Installation; Smart meter should be located after the load and point to Grid …

How to commission smart meter communication with inverter directly Read More »

How to Disassemble or Assemble MID 36-40KTL3-X series inverter

How to disassemble mID 36-40KTL3-X series inverter Procedures: 1. M3 board installation a. Screw 4 pcs M4 screws and Parallel wire B. The M3 leaf spring needs to be installed in the panel hole 2. Main board installation Check whether there are some objects on the insulating sheet and radiator, install the main board on …

How to Disassemble or Assemble MID 36-40KTL3-X series inverter Read More »

How to commission exporting current limitation function on grid inverter

How to commission exporting current limitation function on grid inverter For Growatt Grid inverter, there are 2 solutions for Exporting function limitation. One solution is for single inverter on site. The other solution is to use Shinemaster or SEM for multi inverters on site Single Inverter exporting current limitation MAC Inverter, MID Inverter System overview …

How to commission exporting current limitation function on grid inverter Read More »