SPF 3500-5000ES, SPF 5000TL HVM WPV Troubleshooting
SPF 3500-5000ES, SPF 5000TL HVM WPV Troubleshooting Troubleshooting Download:
SPF 3500-5000ES, SPF 5000TL HVM WPV Troubleshooting Troubleshooting Download:
Connect signal line of Generator to dry contact of off grid inverter Dry contact introduction Select AC input voltage range on LCD Press Eneter for 3 seconds , then go into 3rd option on LCD, Select “Generator”
112 warning is related with exporting current limitation function Meaning: Firstly, you need to understand our exporting current limitation solution: For Single inverter ; Inverter and smart meter system can achieve the exporting current limitation function. In the situation, single Inverter will send the data to smart meter and request the power data from meter. …
How to solve 112 warning on MAX series inverters Read More »
PV SW Set Error on Growatt 40K TL3-NS LCD Display Reason: Default, Dipswitch should be OFF OFF. It means 2 MPPT function will work .If you set others, it will have the fault. 4 PV mode: Only MPPT 2 can work
Off Grid Inverter 02 warning Over temperature warning Testing method 1: a. Access OSS system https://oss.growatt.com/login?lang=en b. Download History data Temperature 1: temperature sensor on mainboard Temperature2: Temperature sensor on DC-DC circuit of mianboard Temperature3: Temperature sensor on MPPT board c. You can confirm which board needs to be replaced based on the 3 temperature …
1. What’s Shinemaster and SME? Shinemaster Led light Meaning: a. “S” means that when exporting current limitation function enables, smart meter is not uploading data b. “L” means that when switching to 4G mode, it will be on c. “RF” , It is not useful, originally, it is preserved for future. d. “PAIR”, it is …
How to commission the communication of Shinemaster or SME (Smart Energy Manager) Read More »
How to configure Datalogger like Shinewifi-S, Shinewifi-X, Shinewifi-F Attention, please! We just update Shinephone version and upgrade to Shinephone above 8.0.0 that has solved the issue which will fail configurating on IOS version above 16 etc. Please remember to download newest Shinephone version above 8.0.0 when you start configuring it. Growatt Datalogger species: Mainly Shinewifi-X, …
How to configure Datalogger like Shinewifi-S, Shinewifi-x, Shinewifi-f Read More »
SPF 3500-5000ES 09Fault 09fault meaning: Bus soft start failed Triggering condition: 1. BUS Voltage is lower than 400V,or Bus voltage is lower than 8 times of battery voltage OR 2. It can’t reach targe voltage in 30 seconds. Testing method: a. Just connect battery into the inverter. Don’t connect Utility input and PV …
OSS system and Server System Introduction Our Platform has 3 account types, including Distributor account, Installer account, end user account . Distributor and Installer account can be registered on OSS system, while end user account can be registered on server system. OSS system: http://oss.growatt.com/ IP: 183.6.231.170 Server System: https://server.growatt.com/ IP: 47.91.67.66 Port: 5279 OSS System …
61Warning on low frequency Inverter Meaning: Sampling error of battery voltage detecting is over 0.5V Solution: Firstly , try to adjust to the battery voltage on LCD. Tool: Calibration Tool.zip ( Software that is used to adjust to battery voltage ) Download: https://drive.google.com/file/d/1V27J5reUXN2iS45viG3X4CU5Goia8pCw/view?usp=sharing USB CP210x_Windows_Drivers.zip (USB cable Driving firmware) Download: https://drive.google.com/file/d/1B_ltn2HiA95Tp3sCpFtNl9qwZ7Sk-EZY/view?usp=sharing procedures: Set real battery …
How to solve 61 warning on low frequency inverter like SPF 12KT HVM Read More »