How to Add Browsing Account On End User Account
How to add browsing account on end user account Procedures 1.Access server.growatt.com 2. Click “Setting” 3. Click “Browse Account” 4. Click “Add” 5. fILL in User info.
How to add browsing account on end user account Procedures 1.Access server.growatt.com 2. Click “Setting” 3. Click “Browse Account” 4. Click “Add” 5. fILL in User info.
MIC Series Troubleshooting Error 200 LCD Display: AFCI Fault Fault Description: DC arcing error Trigger Condition Perform Fourier decomposition on the energy on the PV side. If the energy in the corresponding frequency band exceeds the detection threshold, an error will be reported. If you do not detect, you can change model B08 to B00, …
mic series Degrade mode Introduction Degarde mode 0:No Derating 1: Low GRID voltage 2: High PV Voltage 3: INV OverTemperature 4: High Inner Ambient Temperature 5: High AC voltage 6: High AC voltage 7: Over Frequency 8: Derated by Export Limit (Inverter) 9: Active power ratio is limited 10: n/a 11: Low PV voltage 12: …
SPH 4000-10000 TL3 BH UP introduction UP Model Interface Panel UP models mainly have BAT, PV, AC, EPS and other power interfaces, USB, COM, 485-1/2/3, CAN, NTC, DRMS, METER and other communication interfaces Power Interface BAT Currently compatible with lead-acid batteries and lithium batteries, input range 100V-550V, current 25A BAT Only the SPH model has …
SPH 4000~10000 tL3 BH Standard Model Introduction Attention, please! For single inverter exporting current limitation system, please make sure that Inverter Grid Output 3 phase ( R, S, T) must be same with smart meter R, S,T, it can’t be conntected casually, or battery discharging may meet the trouble. Standard model interface panel Standard models mainly …
SPH 4000~10000 TL3 BH Standard Model Introduction Read More »
Hope Battery upper Software Introduction: ESS_LV_CAN_GeneralMonitor R1.6.4 CAN Tool 1. Config 2. Main Page 3. BCU page 4. BMU page 5. History Data page 6. dataMigrate Click EraseforeverAlarm and clear all fault 7. ParamWrite 8. ProductInfo 9. BCUInfo 10. ModuleInfo 11. Upgrade Page
CT ratio can’t match smart meter Phenomenon Smart meter data can’t match real current data via clamp meter Smart display 3 phase current Real Clamp meter data Reason Analysis Based on smart meter model below, we know that it is 40mA accuracy smart meter, it means that CT ratio must be **/40mA like 120A/40mA,200A/40mA , …
Case Sharing: CT ratio on CT Can’t Match Smart Meter CT Ratio Read More »
How to Solve 61 warning on SPF 5000 ES 61 fault means PV voltage is too high Phenomenon Trigger Condition PV Input has exceeded 480V and last for 1 second OR PV input voltaeg has exceeded 470V and last for 10 seconds Reason 1.For SPF 5000 ES, MAX PV input voltage is 450V, your configuration …
How to Solve 61 Fault on SPF 5000 ES/SPF 5000TL HVM WPV Read More »
What’s Modbus Protocol type Backgroud The Modbus protocol was developed by Modicon (now a brand of Schneider Electric) in 1979. It is the world’s first bus protocol that is actually used in industrial fields. Later, in order to better popularize and promote Modbus Based on the distributed application of Ethernet (TCP/IP), Schneider has transferred the …
Datalogger like Shinewifi-F,Shinewifi-S,Shinewifi-X AP mode introduction Some clients always struggle to configure Datalogger like Shinewifi-F etc. Sometimes, you will meet many situations like always blinking green, even though router is online, fail configuring via Shinephone. In these situations, You can enter into AP mode and configure it. Based on my experience, it can be configured …
Datalogger like Shinewifi-F,Shinewifi-S,Shinewifi-X AP mode introduction Read More »