How To Solve Exporting Current Limitation Issue Perfectly On Min Series

How to solve exporting current limitation issue perfectly on Min series Some clients want to export absolute 0 power to grid. But in real situation, as communication speed limit, it is difficult to do absolute 0 exporting power. Method 1 This method is for our engineers, they have the authority to set the value on …

How To Solve Exporting Current Limitation Issue Perfectly On Min Series Read More »

Why Can You Read Almost 2-3A AC Current Via Multimeter On Utility Input Of SPF Series Inverter

Why can you read almost 2-3A AC current via multimeter on utility input of sPF Series inverter Some clients are curious about the phenomenon, here is the explanation. Phenomenon When clients measure utility input current via multimeter AC current position, they will get 2-3 A AC current. And they will think why the inverter consumes …

Why Can You Read Almost 2-3A AC Current Via Multimeter On Utility Input Of SPF Series Inverter Read More »

MAC 50~70KTL3-X LV/MV Introduction

MAC 50~70KTL3-X LV/MV introduction MAC 50~70KTL3-X LV/MV Datasheet MAC 50~70KTL3-X LV/MV User manual Product Appearance System Principle Bottom Port MAC 50~70KTL3-X has different IO, Mainboard on different models. Boards can’t be swapped each other on different models Board Introduction IO Board Mainboard M3 board Board Function Introduction Mainboard IO board DSP Chip: 280075, NEXT to …

MAC 50~70KTL3-X LV/MV Introduction Read More »

How to Solve That Off Grid Inverter Can’t Be Switched On Or LCD Screen Is Off

How to solve that off grid inverter can’t be switched on or LCD screen is off There are several situations that cause this phenomenon SPF 3500-5000 ES Situation 1: LCD Screen is off, but fans are working and Fault Led light is blinking Reason: 1.Most of time, wrong firmware has been flased by clients. Solution: …

How to Solve That Off Grid Inverter Can’t Be Switched On Or LCD Screen Is Off Read More »

SPF 4000-12000T HVM 19 Warning Troubleshooting

SPF 4000-12000T HVM 19 Warning troubleshooting 1. 19 warning Meaning Battery Disconnect For Low frequency inverter, battery sampling circuit is desinged on control board. 2. 19 warning Test Method Lead acid battery 1. Please confirm battery type, if lead acid battery, please confirm if battery voltage is normal, if normal, most probably battery sampling circuit …

SPF 4000-12000T HVM 19 Warning Troubleshooting Read More »

Wireless Datalogger Configuration Principle

wireless Datalogger Configuration Principle The core of Wifi is actually to use various methods to send the SSID and password of the AP ( Router ) to be connected to the WIFI device( Datalogger ) that requires networking equipment, and then the WIFI device connects to the designated WIFI network to achieve the purpose of …

Wireless Datalogger Configuration Principle Read More »