How to solve ac v outrange or AC Frequency outrange

AC V Outrange Method 1: Remote set 1. Access server.growatt.com via server.growatt.com 2. Click “Setting” 3. Read or Write value into register address 4. confirm Inverter model and download modbus protocol type , then modify corresponding register address a. MAX Modbus protocol type Download If Max Inverter has AC V outrange, you can check register …

How to solve ac v outrange or AC Frequency outrange Read More »

How to solve 112 warning on MAX series inverters

112 warning is related with exporting current limitation function Meaning: Firstly, you need to understand our exporting current limitation solution: For Single inverter ; Inverter and smart meter system can achieve the exporting current limitation function. In the situation, single Inverter will send the data to smart meter and request the power data from meter. …

How to solve 112 warning on MAX series inverters Read More »

Off Grid Inverter 02 warning

Off Grid Inverter 02 warning Over temperature warning Testing method 1: a. Access OSS system https://oss.growatt.com/login?lang=en b. Download History data Temperature 1: temperature sensor on mainboard Temperature2: Temperature sensor on DC-DC circuit of mianboard Temperature3: Temperature sensor on MPPT board c. You can confirm which board needs to be replaced based on the 3 temperature …