Amosplanet

Stay Hungry, Stay Foolish

Shinemaster Register Address Meaning

Shinemaster register address meaning
Register address

0

Shinemaster language, 0: English, 1: Chinese, 2: Portuguese

1

Shinemaster protocol type, 0: Modbus_TCP, 1: Internal

2

version number of this protocol

3

Shinepano Backlight Delay

4

The time interval for Shinemaster to transmit data to the web server, in minutes

5

The initial search address of the inverter for Shinemaster

6

End search address of the inverter for shinemaster

7

super administrator privileges

8

Shinemaster 10 bits SN

9

Inverter inquiring time delay

10

The identification of updating the firmware of Shinemaster 0: normal work, 1: update the firmware

11

The Wifi module cannot use FTP, It is used for the FTP setting of shinemaster updates its own firmware and photovoltaic device firmware

12

DNS configuration of Shinemaster

13

Datalogger Type: 9: Shinelan 12: Shinemaster 20: Shinemaster4G

14

Shinemaster local IP address, Null Server won’t display it

15

Shinemaster local port

16

MAC Physical Address Shinemaster connects to internet

17

Server IP address Shinemaster connects

18

Server Port Shinemaster connects

19

Server Domain Name

20

Shinemaster safety type

21

Shinemaster Firmware version, compatible with FTP

22

Shinemaster Hardware Version

23

Zigbee Network ID

24

Zigbee Network Channel Number

25

Subnet mask of Shinemaster

26

Default Gateway of Shinemaster

27

Wireless Module Type Setting

28

Not Used, PV Peripheral Devices enable settings , these factory states are disabled, Default value: 0, 0, 0,# 0, 0, 0 # 0, 0, 0, #

29

GPS latitude, longitude

30

time zone

31

System time of Shinemaster

32

Shinemaster restart sign, 0: work normally 1: restart Shinemaster

33

Clear Shinepano sign of data recoridng, 0: work normally, 1: clear ShinePano all data recording

34

Correct Touching screen sign on Shinepano

35

Recover factory set sign on Shinemaster 0: work normally

36

Identification of data polling for photovoltaic equipment , 0: Polling for photovoltaic devices

37

Definition of the polling section of Shinemaster on the function code No. 03 of the inverter, there are 2 sections on default: 0, 44 # 45, 89#

38

Shinemaster 30 bits S/N

39

Reserved Parameters

40

Limit the number of inverters monitored by Shinemaster, the default is 0, the valid value is [1,32], other values are illegal

41

communication protection time. When Shinemaster can’t get data from inverter, and it has persisted for a period of time, it will execute restarting . The parameter is used to set and read the time

42

Data Transmiting Mode, 0: protocol transimitting mode, 1: transparent transimitting mode

43

Reserved, Webbox usage

44

Inverter upgrading choice

45

network type: 1, wireless, 2. wired

46

Register Device

47

The first Channel 485 Baud rate, “1”:4800;”2″:9600,”3″:38400, “4”:115200

48

The second Channel 485 Baud rate, “1”:4800;”2″:9600,”3″:38400, “4”:115200

49

Testing mode; 0: Work normally, 1: Testing Mode, 2. Aging mode, 3. Exporting current limitation Test, 4. Get storage data mode

50

SD card status: 0: Normal, 1: Malfunction

64

SIM Card Operator

65

Pairing Enabled

66

Exporting Current limitation Function Enable or Disable

67

Set Exporting current limitation power

68

RF Communication Signal increment

69

Check if succesful since last paring query

70

SCADAMode: 1. Enable 0. Disable

71

DHCP function Enable or Disable

72

1.Get APN automatically 2. Set APN manually

73

Meboost Regular Boiling time

74

Meboost manual mode working time

75

0: Dont’ make R485_1 baud rate fixed 1: When upgrading, make RS 485_1的波特率 fixed

89

Exporting current limitation address : default address is 0

90

Exporting current limitation Channel: Default is second channel

91

Exporting current limitation failure power percentage

92

Exporting current limitation function failure time. 0-5000

93

0: not connected to national grid , 1. connected to grid

94

0: Diable 1:enanble exporting current limiation failure function

95

PF : 0.8-1

96

0: disable adjsuting reactive power 1: Enable adjusting reactive power

97

0: disable reactive power priority 1: enable reactive power priority

98

0: new version exporting current limitation 1: enable old version exporting current limitation

99

0: Reactive power adjusting Scenario 0: NO_1 1: NO_2